Volume 8, Issue 4 (Winter 2012)                   Sci J Iran Blood Transfus Organ 2012, 8(4): 265-271 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Razjou F, Dabirmoghadam A. Comparison of the Bact/Alert blood culture system and manual culture method for detection of aerobic and facultative anaerobic bacterial contamination in platelet concentrates . Sci J Iran Blood Transfus Organ 2012; 8 (4) :265-271
URL: http://bloodjournal.ir/article-1-580-en.html
Abstract:   (19386 Views)

  Abstract

 Background and Objectives

 For reducing bacterial contamination of platelets in the medium, FDA has approved the Bact/Alert for screening the platelet units. This study attempts to compare the Bact/Alert system and the manual culture method as far as the length of time in hours of detection is concerned.

 

 Materials and Methods

 In this interventional and diagnostic study, 15 platelet units were selected randomly among 1332 units and inoculated with 10 CFU/ml of various bacteria including Streptococci, Serratia marcescens, Enterobacter cloacae, Corynebacterium diphteroid, Staphylococcus aureus and Staphylococcus epidermidis which normally contaminate platelet units. These units together with other platelet units in a blind way were tested by both Bact/Alert system and the manual method.

 

 Results

 Regarding the short expiration time of platelet units, if the length of time in hours in detection is considered as a basis for comparison, the Bact/Alert system is significantly superior to the manual method. The medium length of time in hours for detecting the aerobic bacteria by Bact/Alert system is 31 ± 8 hours, compared with the manual method which is 61 ± 11 hours. This shows that Bact/Alert system is nearly 2 times faster than the manual method.

 

 Conclusions

 Bact/Alert culture system compared with the manual method is more rapid and accurate for detection of bacterial contamination thereby improving platelet safety. Regarding serious effects of these contaminations on platelet recipients, it is also necessary to try to reduce them by using GMP.

  

  

Full-Text [PDF 192 kb]   (5667 Downloads)    
Type of Study: Research | Subject: Blood transfusion medicine
Published: 2013/08/28

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Scientific Journal of Iran Blood Transfus Organ

Designed & Developed by : Yektaweb