<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Blood Transfusion</title>
<title_fa>فصلنامه پژوهشی خون</title_fa>
<short_title>bloodj</short_title>
<subject>Medical Sciences</subject>
<web_url>http://bloodjournal.ir</web_url>
<journal_hbi_system_id>91</journal_hbi_system_id>
<journal_hbi_system_user>journal91</journal_hbi_system_user>
<journal_id_issn>1027-9520</journal_id_issn>
<journal_id_issn_online>1735-8248</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/bloodj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>آلودگی باکتریایی فرآورده‌های پلاکتی تهیه شده با کیسه جانبی (همراه و بدون کیسه نمونه‌گیری) در دو مقطع زمانی مختلف در مرکز انتقال خون کرمان</title_fa>
	<title>Evaluation of Bacterial contamination of platelet products by triple packs with and without sampling pouch in two different periods in Kerman Blood Center</title>
	<subject_fa>انتقال خون</subject_fa>
	<subject>Blood Transfusion</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.25pt;&quot;&gt;چکیده&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;سابقه و هدف &lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.25pt;&quot;&gt;&lt;strong&gt;آلودگی باکتریایی در پلاکت&#8204;های کنسانتره، از عوارض شایع و خطرناک انتقال خون در جهان است. هدف از مطالعه حاضر، بررسی آلودگی باکتریایی فرآورده&#8204;های پلاکتی تهیه شده در پایگاه انتقال خون کرمان با روش کشت بود.&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.85pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;مواد و روش&#8204;ها&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:35.35pt;&quot;&gt;&lt;strong&gt;در یک مطالعه توصیفی- مقطعی به صورت تصادفی، 630 نمونه فرآورده پلاکتی در دو گروه (360 نمونه با استفاده از کیسه&#8204; جانبی بدون کیسه نمونه&#8204;گیری و 270 نمونه با استفاده از کیسه&#8204; جانبی همراه با کیسه نمونه&#8204;گیری) وارد مطالعه گردید. این نمونه&#8204;ها در محیط&#8204;های ائوزین متیلن بلو و بلادآگار کشت و پس از 48 ساعت انکوباسیون در 37 درجه سانتی&#8204;گراد، بررسی شدند. تحلیل داده&#8204;ها با استفاده از نرم&#8204;افزار 19 &lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;SPSS&lt;/span&gt;&lt;/strong&gt;&lt;strong&gt; و آزمون&#8204;های آمار توصیفی انجام شد.&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;یافته&#8204;ها&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:35.35pt;&quot;&gt;&lt;strong&gt;از مجموع 630 نمونه کشت داده شده، تعداد 5 مورد(39/1%) آلوده تشخیص داده شد که همگی مربوط به نمونه&#8204;های پلاکت تهیه شده از کیسه&#8204;های جانبی، بدون کیسه نمونه&#8204;گیری بود. باکتری&#8204;های استافیلوکوکوس اپیدرمیدیس(3 مورد) و استافیلوکوکوس ساپروفیتیکوس(2 مورد) از نمونه&#8204;ها جدا شدند. &lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;نتیجه&#8204;گیری&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.25pt;&quot;&gt;&lt;strong&gt;با توجه به پیشرفت&#8204;هایی که در زمینه جمع&#8204;آوری، تهیه و ذخیره پلاکت&#8204;های کنسانتره به وجود آمده است، عفونت باکتریایی ناشی از انتقال پلاکت&#8204;های آلوده به طور چشمگیری کاهش یافته که ارتقاء فرآیندها و استقرار &lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;GMP&lt;/span&gt;&lt;/strong&gt;&lt;strong&gt; ، نقش عمده&#8204;ای در این کاهش داشته است.&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right:36.85pt;&quot;&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;strong&gt;Abstract&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:35.1pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Background and Objectives&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;Bacterial infection following platelet transfusion is a major problem in transfusion medicine. The present study was carried out in order to evaluate the bacterial contamination of platelet concentrates collected at Kerman Regional Educational Blood Center.&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Materials and Methods&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;In this cross-sectional study, 630 random samples of platelet transfusion in both groups (360 subjects using triple bags without sampling pouch and 270 samples using triple bags with sampling pouch) were selected. Bacterial growth of samples of platelet concentrates was studied in blood agar, EMB and thioglycollate broth after 48 hours at 37&amp;deg;C. SPSS 19 has been used for data analysis.&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Results&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;Out of 630 samples of platelet concentrates studied, 5 (1.39%) were found positive for bacterial contamination all taken from the platelet samples prepared by triple bags without sampling pouch. The bacteria identified were as follows: Staph. Epidermidis (n = 3), Staph. saprophyticus (n= 2). In the platelet samples made from triple bags with sampling pouch, there was no contamination.&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Conclusions&amp;nbsp; &lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;Due to advances in the collection, preparation and storage of platelet concentrates, transmitted bacterial infection caused by contaminated platelets dropped significantly. This is due to the efforts of effective quality control processes to improve the quality of blood transfusion&lt;a name=&quot;_GoBack&quot;&gt;&lt;/a&gt;.&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;/p&gt;

&lt;p style=&quot;margin-left:34.85pt;&quot;&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>کلمات کلیدی: خون, انتقال پلاکت, انتقال خون, اهداکنندگان خون</keyword_fa>
	<keyword>Key words: Blood, Platelet Transfusion, Blood Transfusion, Blood Donors</keyword>
	<start_page>243</start_page>
	<end_page>247</end_page>
	<web_url>http://bloodjournal.ir/browse.php?a_code=A-10-786-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M.S.</first_name>
	<middle_name></middle_name>
	<last_name>Razeghi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد صادق</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رازقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460014442</code>
	<orcid>9100319475328460014442</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کرمان ـ ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>N.</first_name>
	<middle_name></middle_name>
	<last_name>Chatr Abnous</last_name>
	<suffix></suffix>
	<first_name_fa>نازنین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>چترآبنوس</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460014443</code>
	<orcid>9100319475328460014443</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کرمان ـ ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>S.</first_name>
	<middle_name></middle_name>
	<last_name>Soleimani</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سلیمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>saeed.soleimanyamoli@gmail.com</email>
	<code>9100319475328460014444</code>
	<orcid>9100319475328460014444</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>بلوار 22 بهمن ـ کرمان ـ ایران ـ کدپستی: 7616859979</affiliation_fa>
	 </author>


	<author>
	<first_name>E.</first_name>
	<middle_name></middle_name>
	<last_name>Kafi</last_name>
	<suffix></suffix>
	<first_name_fa>احسان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کافی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460014445</code>
	<orcid>9100319475328460014445</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کرمان ـ ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
