<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Blood Transfusion</title>
<title_fa>فصلنامه پژوهشی خون</title_fa>
<short_title>bloodj</short_title>
<subject>Medical Sciences</subject>
<web_url>http://bloodjournal.ir</web_url>
<journal_hbi_system_id>91</journal_hbi_system_id>
<journal_hbi_system_user>journal91</journal_hbi_system_user>
<journal_id_issn>1027-9520</journal_id_issn>
<journal_id_issn_online>1735-8248</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/bloodj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>22</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی حساسیت و ویژگی یک دستگاه هموگلوبینومتر تولید شده توسط یک شرکت دانش بنیان در بیماران تالاسمی</title_fa>
	<title>Evaluation of the Sensitivity and Specificity of a Hemoglobinometer Device Produced by a Knowledge-Enterprise Company in Thalassemia Patients</title>
	<subject_fa>هماتولوژي</subject_fa>
	<subject>Hematology</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;چکیده&lt;br&gt;
سابقه و هدف&amp;nbsp;&lt;br&gt;
اندازه&#8204;گیری دقیق هموگلوبین در بیماران تالاسمی نقش حیاتی در مدیریت درمان و پیشگیری از بروز عوارض دارد. دستگاه&#8204;های هموگلوبینومتر به دلیل دقت بالا، سرعت و سهولت عملکرد، ابزارهای مناسبی برای پایش سطح هموگلوبین هستند. این مطالعه با هدف ارزیابی عملکرد یک دستگاه هموگلوبینومتر ساخت یک شرکت دانش&#8204; بنیان به بررسی کارآیی آن در اندازه&#8204;گیری هموگلوبین در مقایسه با دستگاه مرجع می&#8204;پردازد.&amp;nbsp;&lt;br&gt;
مواد و روش&#8204;ها&lt;br&gt;
در این مطالعه مقطعی، هموگلوبین 83 بیمار تالاسمی مراجعه&#8204;کننده به درمانگاه تالاسمی با هموگلوبینومتر و دستگاه مرجع (Sysmex XP-300) اندازه&#8204;گیری شد. تحلیل&#8204;های آماری شامل ارزیابی حساسیت، ویژگی، ارزش اخباری مثبت/منفی، نمودار Bland-Altman ، شاخص همبستگی درون طبقه&#8204;ای (ICC) و منحنی ROC انجام شد.&lt;br&gt;
یافته&#8204;ها&lt;br&gt;
میانگین هموگلوبین اندازه&#8204;گیری شده توسط هموگلوبینومتر g/dL 9/65 &amp;plusmn; 1/40 با میانه g/dL 9/70 بود. تحلیل&#8204;ها نشان داد همبستگی قوی بین دو دستگاه ([ 0.98- 0.94] CI 95% ،&amp;nbsp;&lt;br&gt;
ICC= 0.96%) و&amp;nbsp;عدم اختلاف معنادار در تحلیل Bland- Altman وجود دارد و ضریب تعیین 92/60% می&#8204;باشد. حساسیت (83/90 %)، ویژگی (96/30 %)، ارزش اخباری مثبت (97/90 %)، ارزش اخباری منفی (74/30 %)، دقت کلی (87/90 %)، ضریب کاپا (74/50 %) و بر اساس منحنی ROC ، Cut-off معادل 10/30 محاسبه شد.&lt;br&gt;
نتیجه گیری&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;br&gt;
نتایج هموگلوبینومتر در تشخیص موارد مثبت از دقت بالایی برخوردار بود (97/90 % =PPV). به طوری که در 48 مورد مثبت شناسایی شده تنها یک مورد مثبت کاذب گزارش شد. این ویژگی می&#8204;تواند نشان&#8204;دهنده قابلیت اعتماد بالای دستگاه در شناسایی بیماران تالاسمی نیازمند خون باشد. از طرفی از 35 مورد منفی شناسایی شده توسط این دستگاه، 9 مورد منفی کاذب گزارش شد (74/30 % = NPV) که بیانگر ضرورت بررسی مجدد نتایج منفی با یک دستگاه مرجع یا سایر روش&#8204;های تشخیصی بررسی می&#8204;باشد.&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div&gt;&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;tab-stops:center 175.2pt left 281.2pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;u style=&quot;text-underline:#77787a&quot;&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;color:#2b3990&quot;&gt;A B &lt;/span&gt;&lt;/span&gt;&lt;/u&gt;&lt;/b&gt;&lt;b&gt;&lt;u style=&quot;text-underline:#77787a&quot;&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;S T &lt;/span&gt;&lt;/span&gt;&lt;/u&gt;&lt;/b&gt;&lt;b&gt;&lt;u style=&quot;text-underline:#77787a&quot;&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;color:#2b3990&quot;&gt;R A C T&lt;/span&gt;&lt;/span&gt;&lt;/u&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;i&gt;Background and Objectives&lt;/i&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:inter-ideograph&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-size:8.5pt&quot;&gt;Accurate Haemoglobin measurement in thalassemia patients is critical for effective management and prevention of complications. Hemoglobinometers, due to their precision, rapid results, and ease of use, serve as practical tools for monitoring Hb level. This study evaluates the performance of a hemoglobinometer developed by a knowledge-based company, comparing its efficacy with a standard reference device in measuring haemoglobin level.&lt;/span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;i&gt;Materials and Methods&lt;/i&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:kashida&quot;&gt;&lt;span style=&quot;text-kashida:0%&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-size:8.5pt&quot;&gt;This cross-sectional study was conducted on 83 thalassemia patients referred to the adult thalassemia clinic. Hb levels were measured using both the test hemoglobinometer and the reference device (Sysmex XP-300). Statistical analysis included the evaluation of sensitivity, specificity, positive predictive value (PPV/NPV)/negative predictive value, Bland-Altman diagram, Intracalss Correlation Coefficient (ICC) and Receiver-Operating Characteristic (ROC) curve was done.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:kashida&quot;&gt;&lt;span style=&quot;text-kashida:0%&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;i&gt;Results&lt;/i&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:kashida&quot;&gt;&lt;span style=&quot;text-kashida:0%&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-size:8.5pt&quot;&gt;The median hemoglobinometer readings was 9.65 &amp;plusmn; 1.40 g/dL with a median of 9.70 g/dL. A strong correlation was observed between the two devices (ICC= 0.96%, 95% CI = 0.94- 0.98). The Bland-Altman diagram revealed no significant difference and the coefficient of determination (R&lt;sup&gt;2&lt;/sup&gt;) was calculated 92.60%. The device demonstrated sensitivity of 83.90%, specificity of 96.30%. PPV of 97.90%, NPV of 74.30%, accuracy of 87.90% and a Kappa coefficient of 74.50%. The optimal cut-off based on the ROC curve, was determined to be 10.30. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:kashida&quot;&gt;&lt;span style=&quot;text-kashida:0%&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;i&gt;Conclusions&amp;nbsp; &lt;/i&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:kashida&quot;&gt;&lt;span style=&quot;text-kashida:0%&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;font-size:8.5pt&quot;&gt;The hemoglobinometer demonstrated high diagnostic accuracy for detecting positive cases (PPV: 97.90%), with only one false positive result among 48 positive readings, indicating its suitability for identifying thalassemia patients requiring blood transfusion. However, among negative cases (NPV: 74.30%), 9 false negative cases were recorded out of 35 readings. It emphasizes the necessity of re-evaluating negative results using a reference device or other diagnostic methods.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract>
	<keyword_fa>هموگلوبین‌ها, تالاسمی, واکنش‌های مثبت کاذب, واکنش‌های منفی کاذب</keyword_fa>
	<keyword>Hemoglobins, Thalassemia, False Positive Reactions, False Negative Reactions</keyword>
	<start_page>183</start_page>
	<end_page>195</end_page>
	<web_url>http://bloodjournal.ir/browse.php?a_code=A-10-1642-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sanaz</first_name>
	<middle_name></middle_name>
	<last_name>Asiyabi</last_name>
	<suffix></suffix>
	<first_name_fa>ساناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آسیابی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460026572</code>
	<orcid>9100319475328460026572</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات انتقال خون ـ مؤسسه عالی آموزشی و پژوهشی طب انتقال خون</affiliation_fa>
	 </author>


	<author>
	<first_name>Sedigheh</first_name>
	<middle_name></middle_name>
	<last_name>Amini-Kafiabad</last_name>
	<suffix></suffix>
	<first_name_fa>صدیقه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امینی کافی‌آباد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460026573</code>
	<orcid>9100319475328460026573</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>استاد مرکز تحقیقات فرآورده‌های بیولوژیک و سلامت خون ـ مؤسسه عالی آموزشی و پژوهشی طب انتقال خون</affiliation_fa>
	 </author>


	<author>
	<first_name>Amir</first_name>
	<middle_name></middle_name>
	<last_name>Teimourpour</last_name>
	<suffix></suffix>
	<first_name_fa>امیر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>تیمورپور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460026574</code>
	<orcid>9100319475328460026574</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>استادیار مرکز تحقیقات فرآورده‌های بیولوژیک و سلامت خون ـ مؤسسه عالی آموزشی و پژوهشی طب انتقال خون</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid Reza</first_name>
	<middle_name></middle_name>
	<last_name>Gholizadeh</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قلی‌زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460026575</code>
	<orcid>9100319475328460026575</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات انتقال خون ـ مؤسسه عالی آموزشی و پژوهشی طب انتقال خون</affiliation_fa>
	 </author>


	<author>
	<first_name>Samaneh</first_name>
	<middle_name></middle_name>
	<last_name>Alizadeh Haghighi</last_name>
	<suffix></suffix>
	<first_name_fa>سمانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علیزاده حقیقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9100319475328460026576</code>
	<orcid>9100319475328460026576</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات انتقال خون ـ مؤسسه عالی آموزشی و پژوهشی طب انتقال خون</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Hesam</first_name>
	<middle_name></middle_name>
	<last_name>Rafiee</last_name>
	<suffix></suffix>
	<first_name_fa>محمد حسام</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رفیعی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.rafiee@tmi.ac.ir</email>
	<code>9100319475328460026577</code>
	<orcid>9100319475328460026577</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>استادیار مرکز تحقیقات انتقال خون ـ مؤسسه عالی آموزشی و پژوهشی طب انتقال خون</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
