:: Volume 10, Issue 4 (winter 2014) ::
Sci J Iran Blood Transfus Organ 2014, 10(4): 411-418 Back to browse issues page
Hemoglobin Q-Iran and the importance of using suitable laboratory screening methods-Case report
Sh. Khatami , S. Rouhi Dehnabeh , H. Najmabadi
Abstract:   (9617 Views)
Abstract Background and Objectives Using suitable laboratory methods for the diagnosis of hemoglobinopathies in laboratories not equipped with automatic systems is essential. The correct diagnosis of hemoglobin Q-Iran (α75Asp → His) is important. Case A 33-year-old woman was referred to the national reference globin chain biosynthesis laboratory. The patient's globin chains chromatogram indicated an unknown peak after α globin chain peak. Direct conventional sequencing revealed single G to C missense mutation in the -globin gene. The genetic analysis led to the identification of a rare hemoglobin variant. Conclusions Medical diagnosis laboratories not equipped with modern automatic systems must run solubility test and hemoglobin electrophoresis on citrate agar and cellulose acetate for definite detection of Hb Q-Iran otherwise, it can be regarded as a cause of misdiagnosis with hemoglobin S.
Keywords: Key words: hemoglobin Q, Hemoglobinopathies, screening, Iran
Full-Text [PDF 410 kb]   (1932 Downloads) |   |   Full-Text (HTML)  (2577 Views)  
Type of Study: case report | Subject: Hematology
Published: 2013/12/21


XML   Persian Abstract   Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 10, Issue 4 (winter 2014) Back to browse issues page